“Reduction of X-ray exposure in scoliosis surgery for the patient and OR staff by use of infralaminar hooks (LSZ) from SIGNUS Medizintechnik”
Posterior systems with transpedicular screws as basic element for stabilizing the spinal column have become the gold standard in surgical treatment of spinal deformities and are used in the majority of cases where correction of scoliosis or segmental fixation is required. What is to be done though in cases of severe kyphotic or scoliotic spinal deformities, particularly in connection with developmental anomalies such as hyperplasia or aplasia of the pedicles, which render it more difficult to introduce a screw? Not only does this often lead to an increase in the total time required for surgery, but the X-ray exposure time is also often increased considerably, resulting in unnecessary additional exposure of the patient and OR staff. The question arises whether other fixation methods can be resorted to.
Infralaminar hooks (LSZ) from SIGNUS Medizintechnik provide a useful alternative to pedicle screws in specific sections of the spinal column. Their stability is comparable to that of pedicle screws, as has been proven by a recent biomechanical in-vitro study [1]. The interaction between the infralaminar hooks and the pedicle screws is optimized in the DIPLOMAT Deformity system from SIGNUS Medizintechnik. Enhanced anchorage in cases of hypoplastic pedicles on the concave side, force transmission in translation too, extension of the posterior column and decreased implant density are achieved as a result of the hybrid technique.
You can download the biomechanical study from the SIGNUS website or view it directly on: www.signus.com, free of charge or directly on: http://link.springer.com/article/10.1007/s00586-016-4679-x. Further information on the hybrid technique with the DIPLOMAT Deformity system is also provided on the SIGNUS website.
¹Wilke HJ, Kaiser D, Volkheimer D, Hackenbroch C, Püschel K, Rauschmann M. A pedicle screw system and a lamina hook system provide similar primary and long-term stability: a biomechanical in vitro study with quasi-static and dynamic loading conditions. EurSpine J, 2016 Jul 12. DOI 10.1007/s00586-016-4679-x.
©image rights: SIGNUS Medizintechnik
In the event of publication please kindly send us a voucher copy.
For further information please do not hesitate to contact us.
With best regards
Nadja Schatz
Consulting
m:werk GmbH & Co. KG
Healthcare Communication
Humboldtstraße 11
65189 Wiesbaden
Phone: 0611 / 1 60 86-22
Fax: 0611 / 1 60 86-15
e-mail: schatz@m-werk.de
http://www.m-werk.de
https://www.facebook.com/m.werk.wiesbaden/
https://twitter.com/mwerk_wiesbaden
Director: Reinhard Fuhrmann, René Schütz
HRA 78 77, Local Court Wiesbaden
No virus found in this message.
Checked by AVG – www.avg.com
Version: 2016.0.7752 / Virus Database: 4649/12904 – Release Date: 08/29/16